CFP last date
01 May 2024
Reseach Article

Reliability Assessment of Uninterruptible Power Supply (UPS) System for Medical Operations in Zaria Kaduna State

by Akinsanmi Olaitan, Adedayo Kayode Babarinde, Gerald Kelechi Ijemaru
Communications on Applied Electronics
Foundation of Computer Science (FCS), NY, USA
Volume 3 - Number 6
Year of Publication: 2015
Authors: Akinsanmi Olaitan, Adedayo Kayode Babarinde, Gerald Kelechi Ijemaru
10.5120/cae2015651980

Akinsanmi Olaitan, Adedayo Kayode Babarinde, Gerald Kelechi Ijemaru . Reliability Assessment of Uninterruptible Power Supply (UPS) System for Medical Operations in Zaria Kaduna State. Communications on Applied Electronics. 3, 6 ( December 2015), 23-31. DOI=10.5120/cae2015651980

@article{ 10.5120/cae2015651980,
author = { Akinsanmi Olaitan, Adedayo Kayode Babarinde, Gerald Kelechi Ijemaru },
title = { Reliability Assessment of Uninterruptible Power Supply (UPS) System for Medical Operations in Zaria Kaduna State },
journal = { Communications on Applied Electronics },
issue_date = { December 2015 },
volume = { 3 },
number = { 6 },
month = { December },
year = { 2015 },
issn = { 2394-4714 },
pages = { 23-31 },
numpages = {9},
url = { https://www.caeaccess.org/archives/volume3/number6/473-2015651980/ },
doi = { 10.5120/cae2015651980 },
publisher = {Foundation of Computer Science (FCS), NY, USA},
address = {New York, USA}
}
%0 Journal Article
%1 2023-09-04T19:43:37.078804+05:30
%A Akinsanmi Olaitan
%A Adedayo Kayode Babarinde
%A Gerald Kelechi Ijemaru
%T Reliability Assessment of Uninterruptible Power Supply (UPS) System for Medical Operations in Zaria Kaduna State
%J Communications on Applied Electronics
%@ 2394-4714
%V 3
%N 6
%P 23-31
%D 2015
%I Foundation of Computer Science (FCS), NY, USA
Abstract

The paper presents the reliability assessment of Uninterruptible Power Supply (UPS) systems for medical operations in Zaria. The part stress method was used to assess the reliability. Data on the failure of an APC BK650MI UPS model were used as a case study. Special consideration was given to factors like environment, quality of utility and service personnel, and the results showed that there is a relatively low reliability of the system, for medical operations in Zaria than the country for which the system was designed (USA).

References
  1. Akinsanmi, O., Ekundayo, K. R and Okorie, P.U. 2013. ‘’ Reliability Assessment of an Electronic System: A Case Study of Nokia N1650 Mobile Phone Charger in Zaria, Nigeria’’, Advanced Materials Research, Vol. 824, pp. 170-177.
  2. Abdulahi, M.I., Akinsanmi, O. Muazu.M. B, and Jibril, Y. P. 2007. ‘’ Reliability Assessment of an Electronic System: A Case Study of British Siren in Nigeria’’, Journal of Applied Sciences Research, Vol. 3, No. 12.
  3. Akinsanmi, O. 2004. ‘’Reliability Assessment of UPS in developing Countries’’ M.Eng Thesis. Ahmadu Bello University, Zaria.
  4. Taylor, P. F. U. 1989. ‘’Reliability Assessment and Design of Microcomputers Administrative Purposes in Developing Countries’’. Doctoral Thesis, Ahmadu Bello University, Zaria.
  5. Akinsanmi, O. 2009. ‘’ Determination of the Comparative Reliability of a Nokia 1200 Mobile Phone Charger’’, Journal of Applied Sciences Research, Vol. 5, Issue 11, pp1992.